Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ more

  Windmill Cables

LiHCH Twisted Pair Halogen-free Data Cable

Application

LiHCH Twisted Pair Halogen-free Data Cables are designed for special purpose of data transmission in wind

turbines, suitable for indoor and outdoor installation.

Standards

DIN VDE 0812

Construction

LiHCH Twisted Pair Halogen-free Data Cable

Conductor: Stranded bare copper.

Insulation: PE compound type 2YJ1.

Cable Element: Twisted pairs.

Screen: Tinned copper wire braid.

Sheath: Halogen free compound type HM2.

Technical Data

Rated Voltage Uo/U (Um):350V (≤0.14 mm²); 500V (>0.14 mm²)

Operating Temperatures:flexing: -5℃~+70℃; fixed: -40℃~+70℃

Minimum Bending Radius:flexing: 10×OD; fixed: 7.5×OD

Flame Retardant:DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1

Halogen Free:VDE 0482 part 267/DIN EN 50267-2-1/IEC 60754

Gases Corrosively:VDE 0482 part 267/DIN EN 50267-2-2/IEC 60754

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
2×2×0.14 5.2 37
3×2×0.14 6.2 47
4×2×0.14 6.4 66
5×2×0.14 7.2 76
6×2×0.14 8.2 87
7×2×0.14 8.7 94
10×2×0.14 9.9 119
12×2×0.14 10.0 135
15×2×0.14 11.3 157
18×2×0.14 12.5 190
2×2×0.25 6.1 44
3×2×0.25 7.0 66
4×2×0.25 7.5 81
5×2×0.25 8.2 98
6×2×0.25 9.3 116
7×2×0.25 9.4 120
10×2×0.25 10.6 153
12×2×0.25 11.4 175
15×2×0.25 12.9 213
18×2×0.25 13.7 248
2×2×0.34 7.3 68
3×2×0.34 8.6 92
4×2×0.34 9.6 110
5×2×0.34 10.1 128
6×2×0.34 10.6 147
7×2×0.34 11.0 154
10×2×0.34 13.1 209
12×2×0.34 14.4 245
15×2×0.34 15.2 279
18×2×0.34 16.9 363
2×2×0.5 7.6 76
3×2×0.5 9.0 107
4×2×0.5 10.3 134
5×2×0.5 10.8 150
6×2×0.5 11.4 176
7×2×0.5 11.8 185
10×2×0.5 14.3 275
12×2×0.5 15.1 330
15×2×0.5 17.0 380
18×2×0.5 18.3 450
2×2×0.75 9.0 105
3×2×0.75 10.1 137
4×2×0.75 11.5 166
5×2×0.75 12.4 200
6×2×0.75 12.5 236
7×2×0.75 13.6 255
10×2×0.75 15.7 363
12×2×0.75 17.8 434
15×2×0.75 19.3 500
18×2×0.75 20.6 580

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information